The high flux Flat Sheet Membrane (FSM) from LiqTech is designed for submerged outside-in filtration applications.
The filtration mode is outside-in and cleaning is done by a combination of air-scouring underneath the modules and by back washing along with chemical cleaning.
Configuration | Rectangular with permeate channels inside - Outside-in-filtration |
---|---|
Membrane material | Silicon Carbide (SiC) |
Substrate material | Silicon Carbide (SiC) |
Temperature tolerance | Up to 800°C/1472°F |
Maximum pressure | 3bar/43.5psi |
Operating pressure | Depends on feed characteristics |
---|---|
Maxlmum operation temperature | Determined by system components |
Maxlmum chlorine concentration | Unlimited |
Ph tolerance | 0-14 |
Cleaning | Chlorine,acid,caustis,solvents |
Pore slze | Typical flux at 25°C - Ultra pure water @ 1 bar |
---|---|
UF Membrane | > 3000 LMH / 1764 GFD |
Model | Element dimensions - A (mm/in) x B (mm/inch) x C (mm/inch) | Channel dimension(mm/in) | Membrane area (m²/ft²) |
---|---|---|---|
FSM500100UF-22 | (mm) 100 ± 1.5 x 6 ± 1.0 x 500mm ±2.0 | 2 x 2mm | 0.106 m² |
(inch) 3.9 ± .06 x .24 ± .04 x 19.7inch ±.08 | .08 x .08 inch | 1.1 ft² | |
Bending tolerances on the concave side: Side A:1.0mm/.04inch Side B:N/A Side C:2.0mm/.08 inch |
Flat sheet systems are usually pressureless and submerged into a “feed” tank. It’s often a way to compress a large amount of membrane area in a small footprint. LiqTech’s FSM towers can be customized with different rack sizes and tower heights. Permeate is “sucked” out of the racks, aided by the water level in the tank. This means the membrane coating is on the outside of the sheets, and permeate is drawn in, and is an "outside-in" membrane design.
Number of FSM membranes / racks | Up to 55 FSM per rack / Up to 12 racks |
---|---|
Membrane surface area | Up to 5.8 m²/62.4 ft² per rack - Up to 70 m²/753 ft² per tower |
Tower/module materlal | 316L / 1.4404 or super duplex |
pH tolerance | 0-14 |
Maxlmum operating temperature | Determined by system components |
Operating pressure | Depends on feed characteristics |